Voltage Interface Node
Voltage-type sensors with Vin = 1.8V / 2.5V / 3.3V / 5.0V, required current ≤ 100mA, sensor output signal (Vout) ≤ sensor input voltage (Vin)
Voltage Interface Node
The WiSenMeshWAN® system provides dynamic and autonomous wireless data acquisition from geotechnical sensors using cutting-edge technology. Automated measurement of geotechnical sensors using long-range wireless radio nodes and a SmartGateway allows you to focus on more demanding tasks instead of manual data acquisition and logging.
WiSenMeshWAN® sensor nodes act as both transmitters and receivers, forming a self-organizing dynamic radio mesh network that sends data to a SmartGateway. Users have full remote control of the system through direct, triggered, or scheduled changes, enabling dynamic measurements and report generation.
6C01 Type – WiSenMeshWAN® Voltage Interface Node |
|
---|---|
Basic Features | |
Battery Power | 1 x 3.6V Lithium primary D-Cell (ER34615) |
Accuracy Stop Voltage | 2.7VDC |
Mesh Stop Voltage | 2.1VDC |
Battery Connection | Standard aluminium battery holder |
Working Current (DC) | Max. 210mA |
Local Storage | Min. 450 messages during meshing |
Dimensions (L x W x H) | Interface Node: 100 x 100 x 60 mm |
Weight | 0.6 kg |
External Sensor Size & Weight | Depends on the connected sensor (external cable ≤ 1.0 m) |
Cable Gland | 1 x EMC-CMA12 for external sensor connection |
Wiring Connection | Spring-type terminal |
Primary Sensor | |
Sensor Type: Signal output range (0 to Vcc_Out) / Power input voltage (Vcc_Out) @ max. 100mA
Note: External sensor power-on time: 1 second before sampling. Confirm sensor stabilization time before use. |
|
Accuracy | 0.05% F.S. |
Resolution | 0.18 mV |
Standard System Parameters | |
Temperature | Range: -40 to 85°C; Accuracy: ±1°C; Resolution: 0.1°C |
Voltage | Accuracy: ±0.1V |
WSN Interface | |
Mesh Wireless Interface | WiSenMeshWAN® Protocol |
Sampling Range Selection | |
The “Vcc_Out Hardware Switch” is used to:
Example: For model 6C01, set Vcc_Out to 2.5V to power an EC-5 soil moisture sensor and allow the node to sample between 0 and 2.5V. Note: For other sensors, consult specifications before configuring. |
|
Vcc_Out Switch Settings | |
Switch Position | Output Voltage (Vcc_Out) |
0 (default) | 1.8V (default) |
1 | 2.5V |
2 | 3.3V |
3 | 5.0V |
The sensors are plug and play, working straight out of the box with a self-configuring radio network. Multiple interface options enable integration with third-party sensors from leading geotechnical manufacturers (analog / digital / vibrating wire).
Designed for up to 10 years of maintenance-free operation, the units are IP65 rated or higher, with internal power and radio. Their robust industrial housings allow flexible installation to meet the needs of your monitoring projects.